Improved figure and table management routines

This commit is contained in:
2025-03-25 23:51:31 +00:00
parent 9d6b1bc5b9
commit 9305afd87e
11 changed files with 462 additions and 101 deletions

View File

@@ -32,7 +32,7 @@ the medallion next to the power switch on the front, the DEC423 converter
on the back, or the system jumper position on the system module inside
the box.
\fig{1-1}{MA-0063-87}{Front View of the VAXstation 2000 and MicroVAX 2000 Systems}
\fig{MA-0063-87}{Front View of the VAXstation 2000 and MicroVAX 2000 Systems}
\newpage
\figref{1-2} shows the rear view of the VAXstation 2000 and labels each
@@ -42,7 +42,7 @@ communication port. A VR260 monochrome monitor can be connected to the
ThinWire Ethernet port Supports IEEE 802.3 (Standard Ethernet) network
communications connections over the ThinWire Ethernet cable.
\fig{1-2}{MA-0132-87}{Rear View of the VAXstation 2000 System}
\fig{MA-0132-87}{Rear View of the VAXstation 2000 System}
\newpage
@@ -61,7 +61,7 @@ or a printer. The ThinWire Ethernet port supports IEEE 802.3 (Standard
Ethernet) network communications connections over the ThinWire Ethernet
cable.
\fig{1-3}{MA-0134-87}{Rear View of the MicroVAX 2000 System}
\fig{MA-0134-87}{Rear View of the MicroVAX 2000 System}
\section{Mass Storage Expansion Box for Both Systems}
@@ -74,11 +74,11 @@ The tape drive expansion box contains a TK50 tape drive and a controller
board. Each expansion box contains a power supply, a resistor load board
(to regulate the power supply), and the drive.
\fig{1-4}{MA-0065-87}{Front View of the Hard Disk Expansion Box}
\fig{MA-0065-87}{Front View of the Hard Disk Expansion Box}
\newpage
\fig{1-5}{MA-0064-87}{Front View of the Tape Drive Expansion Box}
\fig{MA-0064-87}{Front View of the Tape Drive Expansion Box}
\newpage
@@ -90,7 +90,7 @@ disk expansion box to the system. Port C is reserved for future options.
\figref{1-6} shows the back of a MicroVAX 2000 system box with an expansion
adapter.
\fig{1-6}{MA-0135-87}{System Box with Expansion Adapter}
\fig{MA-0135-87}{System Box with Expansion Adapter}
\newpage
@@ -115,9 +115,9 @@ connected to the system module through two 40-conductor cables.
\figref{1-7} shows the locations of the FRUs in the system box. \figref{1-8}
shows the locations of the FRUs in the expansion boxes.
\fig{1-7}{MA-0150-87}{FRU Locations in the System Box}
\fig{MA-0150-87}{FRU Locations in the System Box}
\newpage
\fig{1-8}{MA-0133-87}{FRU Locations in the Expansion Boxes}
\fig{MA-0133-87}{FRU Locations in the Expansion Boxes}