\chapter{Testing and Troubleshooting}
|
|
\setcounter{page}{1}
|
|
|
|
\section{Introduction}
|
|
|
|
This chapter describes how to test and troubleshoot the VAXstation 2000
|
|
and the MicroVAX 2000 systems. Differences between the VAXstation 2000
|
|
and the MicroVAX 2000 are specifically identified in the text.
|
|
|
|
This chapter contains the following sections.
|
|
|
|
\begin{itemize}
|
|
\item How to use console mode: determining the console device, enter
|
|
ing console mode, exiting console mode, utilizing the diagnostic
|
|
console device, and where to find a list of the console commands.
|
|
\item How to run the diagnostic tests and interpret the error codes for
|
|
each test: power-up tests, self-test, and system exerciser.
|
|
\item How to troubleshoot all devices in the system.
|
|
\item How to use the utilities.
|
|
\end{itemize}
|
|
|
|
\section{Using Console Mode}
|
|
|
|
The VAXstation 2000 and the MicroVAX 2000 systems have two modes
|
|
of operation: program mode and console mode. Normal operation of the
|
|
VAXstation 2000 and the MicroVAX 2000 is in program mode, that is, with
|
|
the operating system controlling the system. Console mode allows the user
|
|
to control the system from the console terminal using the console com
|
|
mands described in \hyperlink{appendix.b}{Appendix B}. Console mode is contained in ROM on
|
|
the system module.
|
|
|
|
Testing is done while in console mode. The system returns the \console
|
|
prompt when it is in console mode. \tabref{2-1} lists the prompts and the
|
|
mode of operation each prompt represents.
|
|
|
|
\newpage
|
|
|
|
\begin{tbl}{Prompts}{c l}
|
|
\textbf{Prompt} & \textbf{Mode of operation}\\
|
|
\hline
|
|
{>}{>}{>} & Console mode. Console commands are listed in \hyperlink{appendix.b}{Appendix B}. \\
|
|
\$ & Program mode (VMS operating system) \\
|
|
\% & Program mode (Ultrix operating system) \\
|
|
\end{tbl}
|
|
|
|
\subsection{Determining the Console Device}
|
|
|
|
The console device for a VAXstation 2000 system is the keyboard (LK201)
|
|
and monitor (VR260) connected to the video port. The keyboard inputs
|
|
commands at 4800 baud and the monitor displays output from the video
|
|
circuits.
|
|
|
|
The console device for a MicroVAX 2000 system is the terminal (VT220 or
|
|
similar terminal) connected to connector 1 on the DEC423 converter. The
|
|
terminal operates at 9600 baud.
|
|
|
|
\subsection{Entering Console Mode}
|
|
|
|
Console mode is entered any time the CPU halts. The CPU can be halted
|
|
automatically or manually. A halt means that CPU control has passed
|
|
control from the operating system to the console mode program in ROM. If
|
|
the system halts the CPU, then the console mode program checks the
|
|
nonvolatile RAM (NVR) for user-defined instructions on how to handle the halt.
|
|
If you manually halt the CPU, the system enters console mode program
|
|
immediately without checking the NVR for instructions.
|
|
|
|
You can manually halt the CPU and enter console mode by one of the
|
|
following methods.
|
|
|
|
\begin{itemize}
|
|
\item HALT button -- Press the halt button. It is located next to the printer port
|
|
on the back of the system box. The \console prompt is displayed when
|
|
ready for console commands.
|
|
\item BREAK key -- Press the BREAK key on the diagnostic console device
|
|
that is connected to the printer port with the BCC08 cable. The \console
|
|
prompt is displayed when ready for console commands.
|
|
\end{itemize}
|
|
The system automatically halts the CPU for the following reasons.
|
|
\begin{itemize}
|
|
\item After power-up testing -- If the default recovery action is halt, the system
|
|
automatically halts the CPU and enters console mode after power-up
|
|
tests are complete. See Section 2.5.4 for information on setting the
|
|
default recovery actions.
|
|
\item For a boot failure -- If the system fails to boot properly, the system
|
|
automatically halts the CPU and enters console mode. See Section 2.5.2
|
|
for information on setting the default boot device.
|
|
\item On a system error -- If the CPU detects a severe corruption of its
|
|
operating environment, it halts and reads the default recovery action in the
|
|
NVR. The default recovery action can be restart, boot, or halt. When
|
|
it is restart and the restart fails, then the system automatically tries to
|
|
boot the operating system software. If the boot fails, the CPU halts and
|
|
enters console mode. When the default recovery action is boot and the
|
|
boot fails, the CPU halts and enters console mode. When the default re
|
|
covery action is halt, the CPU unconditionally halts and enters console
|
|
mode.
|
|
\end{itemize}
|
|
|
|
One other way to halt the CPU is when the operating system software
|
|
executes a halt instruction. The CPU then reads the default recovery action in
|
|
the NVR and acts on it as described above.
|
|
|
|
\subsection{Exiting Console Mode}
|
|
|
|
Console mode is exited by typing one of the following console commands.
|
|
|
|
\begin{itemize}
|
|
\item BOOT -- This command initializes the CPU and boots the operating
|
|
system software from the device specified. If no device is specified, the
|
|
system searches each on-line device until the operating system software
|
|
|s found. The boot command starts the system similar to when power
|
|
is turned on except that the power-up tests are not run. If the system
|
|
attempts to boot over the net (ESA0) and no software is available on
|
|
another node, the system keeps looking for the software indefinitely.
|
|
If a boot message for the operating system software does not appear
|
|
shortly after the Ethernet boot message (ESA0) is displayed, then you
|
|
must press the halt button to abort the Ethernet boot. If you still need
|
|
to boot over the Ethernet, make sure the node with the operating system
|
|
software is operating normally and the software is loaded. Run the
|
|
Ethernet loopback Utility (TEST 90) to check the networking capability
|
|
of the system if the Ethernet boot continues to fail.
|
|
|
|
When a boot is invoked using this boot command, you can specify
|
|
several boot command flags by bit encoding the flags in a flag word
|
|
specified with the /R5: qualifier. These command flags are listed in
|
|
Paragraph 2.5.3.
|
|
|
|
\item CONTINUE -- This command instructs the CPU to continue the
|
|
operating system software at the address contained in the program counter
|
|
(PC). This command starts up the operating software where it was halted
|
|
provided no console test commands were run. Running a test command
|
|
alters the PC and memory so that the operating system software cannot
|
|
be started properly by entering the continue command. If a test command
|
|
was entered, use the boot command to start the operating system
|
|
software. The continue command is similar to the start command. The
|
|
start command can specify the address to Start the operating software
|
|
and the continue command has the operating software continue where
|
|
it left off.
|
|
|
|
\item START -- This command starts the operating system software at a
|
|
specified address. If no address is given, the contents of the PC are used.
|
|
However, running a test command alters the PC and memory so that the
|
|
operating system software cannot be started properly by entering the
|
|
start command. If a test command was entered, use the boot command
|
|
to start the operating system software.
|
|
|
|
\end{itemize}
|
|
|
|
\subsection{Diagnostic Console Device}
|
|
|
|
There is a diagnostic console device available on the VAXstation 2000. The
|
|
MicroVAX 2000 can use this device if the DEC423 Converter is removed.
|
|
|
|
The diagnostic console device can be utilized by connecting a terminal (such
|
|
as the VT100 or VT220) to the printer port with the special BCC08 cable.
|
|
The terminal operates at 9600 baud. Field service technicians can use this
|
|
terminal as a diagnostic tool to isolate a problem in the normal console
|
|
device.
|
|
|
|
To use this diagnostic console device you must turn off power, connect the
|
|
BCC08 cable to the printer port and terminal, and then turn power back on.
|
|
The diagnostic console device now controls the system. The normal console
|
|
monitor displays video test patterns on the VAXstation 2000 when the video
|
|
circuits are tested. The normal console keyboard does not operate.
|
|
|
|
\subsection{Console Commands}
|
|
|
|
Console commands are listed in \hyperlink{appendix.b}{Appendix B}.
|
|
\newpage
|
|
\section{Testing}
|
|
|
|
Testing procedures on the VAXstation 2000 and the MicroVAX 2000 systems
|
|
are almost identical. The differences between the systems are explained
|
|
where applicable. All diagnostic tests are ROM-based and testine is done
|
|
while in console mode. Tests are executed in either of two ways:
|
|
|
|
\begin{itemize}
|
|
\item Automatically -- When power is turned on the power-up tests begin.
|
|
\item Manually -- By entering one of the console test commands on the
|
|
console terminal. See \hyperlink{appendix.a}{Appendix A} for a complete listing of the test commands.
|
|
\end{itemize}
|
|
|
|
\subsection{Power-up Tests}
|
|
|
|
Power-up tests run each time the system power is turned on. Power-up
|
|
testing consists of a sequence of tests executed for each device installed in
|
|
the system. The test number of each device is listed on the power-up screen
|
|
display as the device is tested. \figref{2-1} shows an example of the powerup
|
|
screen display. The first line indicates the CPU name (KA410-A) and the
|
|
ROM version (V1.0). The test numbers are listed next in descending order
|
|
from the first test, F, to the final test, 1. TEST F will have an underscore
|
|
after it on the MicroVAX 2000 to indicate that TEST F was not run. Note in
|
|
\figref{2-1} that tests 4, 3, 2, and 1 have an underscore (\_) immediately after
|
|
them. This underscore indicates that there is no option device installed for
|
|
that test; thus, no tests are done. TEST F has an underscore after it on the
|
|
MicroVAX 2000 systems because the monochrome video circuits are not
|
|
used by the MicroVAX 2000. No other test numbers can have underscores
|
|
after them. An asterisk (*) after TESTS 4 through 1 indicate that an option is
|
|
installed, but its ROM is destroyed and the Option device must be replaced.
|
|
Only TESTS 1 through 4 can have an asterisk after them. \figref{2-2} lists
|
|
the symbols that can appear in between the tests and what they indicate.
|
|
|
|
\begin{ttfig}{Example of Power-up Tests Screen Display}
|
|
KA410-A V1.0
|
|
F...E...D...C...B...A...9...8...7...6...5...4_..3_..2_..1_..
|
|
\end{ttfig}
|
|
|
|
\figref{2-2} lists the definitions of the symbols that appear between the test
|
|
numbers in the power-up test countdown.
|
|
|
|
\begin{ttfig}{Power-up Symbols Defined}
|
|
... Device tested successfully or has a soft error
|
|
?.. Device has a hard error
|
|
_.. Device not installed or not tested
|
|
*.. Device installed but its ROM is destroyed
|
|
\end{ttfig}
|
|
|
|
If any hard errors (errors that indicate the device must be replaced for
|
|
proper operation) are found during power-up testing, a question mark is
|
|
placed after the failing test number during the countdown sequence. An
|
|
error summary of all errors detected is listed after the power-up sequence
|
|
is complete. Two question marks in the error summary indicate a hard error.
|
|
Error codes that indicate the status or soft errors do not put a question mark
|
|
after the failing test number in the sequence, but do list the error code in the
|
|
error summary. \figref{2-3} shows the power-up screen display with a hard
|
|
error found in TEST F and a soft error found in TEST E. The error summary
|
|
for each failed device is displayed before the boot sequence is started.
|
|
However, the screen usually scrolls so fast when the system starts to boot
|
|
that you may not be able to see what the error summary contained (if there
|
|
was an error summary). To see what errors the power-up tests found, press
|
|
the halt button and enter TEST 50 on the console terminal. TEST 50 is the
|
|
command for bringing up the configuration table. The configuration table
|
|
is created during power-up testing. This configuration table contains all of
|
|
the error codes listed in the power-up error summary as well as error codes
|
|
for all devices installed in the system. The error codes in the configuration
|
|
table are updated every time self-test is run. See Paragraph 2.5.1 for an
|
|
explanation of how to use the configuration table.
|
|
|
|
Each error summary consists of one or two question marks, a test number,
|
|
the ID number of the failed device, and an eight-digit error code. For example,
|
|
in \figref{2-3}, the first line of the error summary shows a hard error
|
|
for TEST F, a device ID number of 00B0, and an error code of 0001.F002.
|
|
The second line shows a soft error for TEST E, a device ID of 0040, and an
|
|
error code of 0000.0005. \hyperlink{subsubsection.2.3.1.1}{Section 2.3.1.1} describes the error codes.
|
|
\newpage
|
|
\begin{ttfig}{Example of Power-up Tests Screen Display with Errors.}
|
|
KA410-A V1.0
|
|
|
|
F?..E...0...C...B...A...9...8...7...6...5...4_..3_..2_..1_..
|
|
|
|
?? F 00B0 0001.F002
|
|
? E 0040 0000.0006
|
|
\end{ttfig}
|
|
|
|
If there is a fatal error in the NVR during power-up testing, the system stops
|
|
testing the other devices and displays ?14 TOY ERR on the screen. When
|
|
this happens, the only way to determine the cause of the problem is by
|
|
viewing the LEDs on the keyboard. One of the LEDs will be lit to indicate
|
|
the failing module. \tabref{2-2} lists the LEDs and which module has failed.
|
|
|
|
\begin{tbl}{Keyboard LEDs Defined}{l l}
|
|
\textbf{Keyboard LED} & \textbf{Failing module}\\
|
|
\hline
|
|
Hold Screen & System module \\
|
|
Lock & Not used \\
|
|
Compose & ThinWire Ethernet option module \\
|
|
Wait & Not used \\
|
|
\end{tbl}
|
|
|
|
Once power-up testing is complete and no fatal or hard errors are found, the
|
|
system boots the operating system software. Both the VAXstation 2000 and
|
|
the MicroVAX 2000 boot the operating system software the same. The only
|
|
difference between the two is that the VAXstation 2000 clears the console
|
|
screen before it boots and the MicroVAX 2000 does not. If a default boot
|
|
device is loaded in the NVR, the system boots off of that device. If no
|
|
default device is loaded in the NVR, the system searches every on-line
|
|
storage drive for the operating software. DUA2 is searched first if a floppy
|
|
diskette is loaded. Otherwise, it is not searched at all. The hard disks are
|
|
searched next, DUA0 then DUA1. MUA0, the tape drive, is checked after
|
|
the hard disk drives if it is installed and a cartridge is loaded. Finally, the
|
|
system searches the Ethernet network for the software and ESA0 is listed
|
|
on the screen. The system continues to search the Ethernet network until
|
|
the operating system software is found.
|
|
\newpage
|
|
\subsubsection{Power-up Test Error Codes}
|
|
|
|
The power-up test error codes indicate status and/or error information. Any
|
|
errors found by power-up tests are listed in the error summary after the
|
|
power-up test countdown sequence. This summary, if any, gives you a brief
|
|
summary of the errors. \tabref{2-3} lists the test numbers and the devices that
|
|
are tested during that particular test. To look at the complete list of devices
|
|
and the status of that device, you must display the configuration table. The
|
|
configuration table lists every device in the system and also lists the results
|
|
of the self-test and power-up tests and is updated each time self-test is run.
|
|
The error codes for each device in the configuration table are explained in
|
|
the troubleshooting section for that individual device. Remember that the
|
|
configuration table contains the results of the self-test and power-up tests
|
|
and not the results of the system exerciser. \figref{2-4} shows an example
|
|
of the configuration table and for an explanation of the configuration table,
|
|
see \hyperlink{subsection.2.5.1}{Paragraph 2.5.1}.
|
|
|
|
|
|
\begin{ttfig}{Example of the Configuration Table}
|
|
>>> TEST 50
|
|
|
|
KA410-A V1.0
|
|
ID 08-00-2B-02-CF-A4
|
|
|
|
?? MONO 0001.F002
|
|
? CLK 0000.0005
|
|
NVR 0000.0001
|
|
DZ 0000.0001
|
|
00000001 00000001 00000001 00000001 00000001 000012A0
|
|
MEM 0002.0001
|
|
00200000
|
|
MM 0000.0001
|
|
FP 0000.0001
|
|
IT 0000.0001
|
|
HDC 1710.0001
|
|
000146B8 00000000 00000320
|
|
TPC 0202.0001
|
|
FFFFFF03 01000001 FFFFFF06 FFFFFF05 FFFFFF05 FFFFFF05 ...
|
|
SYS 0000.0001
|
|
NI 0000.0001 V1.0
|
|
>>>
|
|
\end{ttfig}
|
|
\newpage
|
|
The most common good error code is 0000.0001. There are, however, some
|
|
devices that use the first four digits in the error code to indicate the status
|
|
of the device and the last four digits to indicate the error found on the
|
|
device. The memory (MEM) error code, for instance, contains 0002.0001
|
|
which indicates two megabytes of memory is available (0002.) and no error
|
|
found (.0001). On devices like these, the last four digits always indicate
|
|
.0001 as a good (non-error) indication.
|
|
|
|
Some error codes indicate no error at all and give a status of the device
|
|
such as the clock (CLK) which shows that the date and time has not been
|
|
set. This is not an error, just a status of the clock circuits.
|
|
|
|
Any error code other than 0000.0001 on the MONO, MM, FP, IT, or SYS
|
|
devices indicates a hard error and that device must be replaced for proper
|
|
operation of the system. The other devices such as CLK, NVR, DZ, MEM,
|
|
HDC, TPC, and NI may have a status or a soft error message in the error
|
|
codes and may still operate normally.
|
|
|
|
See the troubleshooting procedures section (Paragraph 2.4) for each device
|
|
to determine whether or not the error code indicates a fault or a status for
|
|
the device.
|
|
|
|
\subsection{Self-test}
|
|
|
|
Self-test allows you to test every device again individually, a few at a time,
|
|
or all of them sequentially just like power-up tests. To individually test a
|
|
device, enter TEST \# where \# is the test number of the device you want
|
|
tested. \tabref{2-3} lists the test numbers and the devices tested by those
|
|
numbers. \figref{2-5} shows an example of running self-test successfully on
|
|
the disk controller.
|
|
|
|
\begin{ttfig}{Example of Running Self-test on the Disk Controller}
|
|
>>> TEST 7
|
|
7...
|
|
>>>
|
|
\end{ttfig}
|
|
|
|
\newpage
|
|
|
|
To test a group of devices, enter TEST followed by the test number of the
|
|
first device to be tested and then the test number of the last device to be
|
|
tested. \figref{2-6} shows an example of testing a group of devices. In \figref{2-6},
|
|
all tests between C and 4 are tested successfully. Note that you cannot
|
|
pick and choose which devices to test between C and 4, all tests between
|
|
C and 4 are tested when entered as a group.
|
|
|
|
\begin{ttfig}{Example of Running a Series of Self-tests}
|
|
>>> TEST C 4
|
|
C...B...A...9...8...7...6...5...4_..
|
|
>>>
|
|
\end{ttfig}
|
|
|
|
To test all devices, enter TEST F 1. The MicroVAX 2000 skips over the
|
|
MONO video test (TEST F) since it does not use the video circuits.
|
|
|
|
\begin{tbl}{Self-test Commands}{p{2cm} p{8cm}}
|
|
\raggedright\textbf{Test\newline Number} & \textbf{Device\newline Tested} \\
|
|
\hline
|
|
1 & Option module (Network Interconnect module) (NI) \\[0.5em]
|
|
2 & Option module (not available) \\[0.5em]
|
|
3 & Option module (not available) \\[0.5em]
|
|
4 & Option module (not available) \\[0.5em]
|
|
5 & Interrupt Controller and ThinWire Ethernet ID ROM (SYS) \\[0.5em]
|
|
6 & Tape Controller. (TPC) \\[0.5em]
|
|
7 & Disk conroller. (HDC) \\[0.5em]
|
|
8 & Interval timer. (IT) \\[0.5em]
|
|
9 & Floating point unit. (FP) \\[0.5em]
|
|
A & Memory management unit. (MM) \\[0.5em]
|
|
B & Memory. (MEM) \\[0.5em]
|
|
C & DZ Controller. (DZ) \\[0.5em]
|
|
D & Non-volatile RAM. (NVR) \\[0.5em]
|
|
E & Time-of-year dock. (CLK) \\[0.5em]
|
|
F & Base video (MONO) (VAXstation 2000 only) \\[0.5em]
|
|
\end{tbl}
|
|
|
|
\subsubsection{Self-test with Loopback Connectors}
|
|
|
|
Customer mode self-test does not test the drivers or the lines of the serial
|
|
line conroller (DZ) since loopbacks are not used. Run self-test in field
|
|
service mode to test the DZ drivers by installing the loopback connectors on
|
|
the back of the system. Follow one of the procedures below.
|
|
|
|
To test the DZ on VAXstation 2000, install a loopback (p/n 29-24795) on
|
|
the 25-pin communication port and a loopback (p/n 29-24794) on the 9-pin
|
|
printer port. Run TEST C. You cannot use loopback connectors if you are
|
|
using the diagnostic console device with the BCC08 cable on the printer
|
|
port since there is no loopback connector for the video port.
|
|
|
|
To test the DZ on MicroVAX 2000, install a loopback (p/n 29-24795) on the
|
|
25-pin communication port and install an MMJ loopback on both ports 2
|
|
and 3. Run TEST C.
|
|
|
|
\textbf{NOTE:} \textit{The ThinWire Ethernet port on the back of the
|
|
system box must be terminated properly when running diagnostics on the
|
|
network option (TEST 1) othetwise an error code of 0000.7001 or greater
|
|
is listed in the configuration table.}
|
|
|
|
\subsubsection{Self-test Error Codes}
|
|
|
|
\figref{2-7} shows how an error is displayed if found during self-test. This
|
|
example shows an error on the disk controller during self-test. The 84 FAIL
|
|
indicates an error was found on the device tested. You must display the
|
|
configuration table (TEST 50) after self-test is complete to see the error code,
|
|
if there is an error during self-test, since the error codes do not appear on
|
|
the screen. The configuration table lists every device in the system, fists the
|
|
results of the self-test and power-up tests, and is updated each time self-test
|
|
is run. The error codes for each device in the configuration table are
|
|
explained in the troubleshooting section for that individual device. Remember
|
|
that the configuration table contains the results of the self-test and power-up
|
|
tests and not the results of the system exerciser. See Paragraph 2 5 1 for an
|
|
explanation of the configuration table.
|
|
|
|
\newpage
|
|
\begin{ttfig}{Example of a Self-test Error on the Disk Controller}
|
|
>>> TEST 7
|
|
7?..
|
|
84 FAIL
|
|
>>>
|
|
(You must display the configuration table to see the error code)
|
|
\end{ttfig}
|
|
|
|
\newpage
|
|
|
|
\subsection{System Exerciser Diagnostics}
|
|
|
|
The system exerciser simulates a worst-case situation test for each device
|
|
and checks how the device operates under these conditions. It does not use
|
|
the configuration table to list its results of the tests. The system exerciser
|
|
has a separate display that appears on the screen as the exerciser is running.
|
|
Any errors found are displayed in the exerciser display. When examining
|
|
the exerciser display, a single question mark in the far left column indicates
|
|
a soft error, a double question mark indicates a hard error, and the absence
|
|
of question marks indicate success. \figref{2-8} shows an example of the
|
|
exerciser display.
|
|
|
|
The system exerciser exercises most of the devices. However, some devices
|
|
such as the memory management unit (MM) and the interval timer (IT) are
|
|
tested through the testing of other devices and are not displayed. Of the
|
|
devices the exerciser does exercise, it runs each one sequentially until all
|
|
have been run once, then it runs them all at the same time (worst-case).
|
|
This type of testing usually finds any intermittent failures.
|
|
|
|
The system exerciser has two modes: customer mode and field service
|
|
mode. Customer mode system exerciser (TEST 0) does not use loopback
|
|
connectors and does not fully test all of the devices. Field service mode system
|
|
exerciser requires loopback connectors installed and removable media
|
|
from the maintenance kit inserted and loaded. You must initialize the floppy
|
|
diskette in the maintenance kit with a special diagnostic key so the exerciser
|
|
can perform write tests on the RX33. Refer to Paragraph 2.5.11 for more
|
|
Information on creating the special diagnostic keys. Once the floppy has
|
|
been initialized, load it into the RX33 (if a full read/write test of the RX33 is
|
|
necessary) before you run the system exerciser in field service mode. You
|
|
must also initialize the COMPACTape cartridge in the maintenance kit with
|
|
a special diagnostic key so the exerciser can perform read/write tests on
|
|
the TK50. Refer to Paragraph 2.5.11 for more information on creating the
|
|
special diagnostic keys. Once the COMPACTape cartridge has been initial
|
|
ized, load it into the TK50 (if a full read/write test of the TK50 is necessary)
|
|
before you run the system exerciser in field service mode. If the RX33 or
|
|
the TK50 are not loaded with the special-key media, the system exerciser
|
|
does not do destructive writes to them and tests them the same as it does
|
|
during the customer mode system exerciser. This special-key on the media
|
|
prevents the exerciser from accidentally destroying data on the customers
|
|
floppy diskette or COMPACTape cartridge. The field service mode system
|
|
exerciser is available in a run once (TEST 101) and a run forever (TEST 102)
|
|
configuration.
|
|
|
|
\newpage
|
|
|
|
\subsubsection{System Exerciser Diagnostic Commands}
|
|
\tabref{2-4} lists the system exerciser diagnostic commands.
|
|
|
|
\begin{tbl}{System Exerciser Diagnostic Commands}{p{0.2\textwidth} p{0.8\textwidth}}
|
|
\textbf{Test Commands} & \textbf{Description of Commands} \\
|
|
\hline
|
|
|
|
0 & Runs customer mode system exerciser. It exercises
|
|
each device once sequentially, then exercises them
|
|
simultaneously, and stops when the slowest device
|
|
finishes its second pass. No loopback connectors
|
|
and no removable media required. \\
|
|
|
|
101 & Runs field service system exerciser. It exercises
|
|
each device once sequentially, then exercises them
|
|
simultaneously, and stops when the slowest device
|
|
finishes its second pass. Do not stop the exerciser
|
|
before it finishes exercising every device twice
|
|
(second pass). Loopbacks and removable media required. \\
|
|
|
|
102 & Runs field Service system exerciser. It exercises each
|
|
device once sequentially and then exexcises them
|
|
simultaneously until you enter a \keystroke{CTRL}-\keystroke{C}.
|
|
Note that the exerciser takes up to thirty seconds
|
|
to stop after you enter \keystroke{CTRL}-\keystroke{C}. Do
|
|
not stop the exerciser until every device is exercised
|
|
twice (second pass). Also, do not press the halt button
|
|
to stop the exerciser. Loopbacks and removable media required. \\
|
|
\end{tbl}
|
|
|
|
When the exerciser is started, PRA0 is displayed and the monitor connected
|
|
to the video port on the VAXstation 2000 blinks white and black several
|
|
times while the monochrome circuits are being tested. The results of the
|
|
MONO tests are then displayed on the console screen. MicroVAX 2000
|
|
does not use the MONO circuits and, therefore, does not test them. The
|
|
DZ test results are the first to be displayed on the console screen. The rest
|
|
of the devices are then exercised one at a Urne and the results are listed
|
|
on the display. The console displays the results of each device until the
|
|
last device is finished testing. When the last device is done, the exerciser
|
|
starts running all devices together at the same time. When this happens, the
|
|
monitor connected to the video port starts blinking again until the slowest
|
|
device finishes testing. On the MicroVAX 2000, the console terminal holds
|
|
the first pass display until the slowest device is done testing then displays a
|
|
new exerciser display. The console screen (VAXstation 2000 and MicroVAX
|
|
2000) displays the results of each device tested. This display stays on the
|
|
screen for about 10 seconds, then the exerciser starts running all devices
|
|
together again if TEST 102 was entered. If TEST 0 or TEST 101 was entered,
|
|
the exerciser stops after the slowest device is done testing. The halt message
|
|
is displayed when the exerciser is stopped.
|
|
|
|
To run the field service mode system exerciser on VAXstation 2000, install a
|
|
loopback (p/n 29-24795) on the 25-pin communication port and a loopback
|
|
(p/n 29-24794) on the 9-pin printer port. Insert and load the floppy diskette
|
|
and TK50 COMPACTape cartridge from the maintenance kit if the system
|
|
has these devices installed. Run the exerciser by entering TEST 101 or TEST
|
|
102. If you are using the diagnostic console device, you will get errors on
|
|
the DZ line since there is no loopback for the video port.
|
|
|
|
To run the field service mode system exerciser on MicroVAX 2000, install
|
|
a loopback (p/n 29-24795) on the 25-pin communication port and install an
|
|
MMJ loopback on both ports 2 and 3. Insert and load the scratch floppy
|
|
diskette and scratch TK50 COMPACTape cartridge from the maintenance
|
|
kit if the system has these devices installed. Run the exerciser by enter
|
|
ing TEST 101 or TEST 102. If the scratch floppy or TK50 cartridge is not
|
|
installed, the system tests those devices the same as in customer mode.
|
|
|
|
\subsubsection{System Exersiser Error Codes}
|
|
|
|
\figref{2-8} shows an example of the system exerciser display while running
|
|
the system exerciser in field service mode. Customer mode gives the same
|
|
display, but with a CU in place of the FS on the top of the display.
|
|
|
|
\begin{ttfig}{System Exerciser Display Example}
|
|
KA410-A V1.0 01 FS
|
|
|
|
F 00B0 MONO 0000.0001 2 0 00:00:55.01
|
|
C 0080 DZ 0000.0001 5 0 00:01:28.03
|
|
B 0010 MEM 0175.0001 2 0 00:02:03.07
|
|
7 0090 HDC 2000.0001 4 0 00:02:08.58
|
|
? 0700.7091 0 00:02:08.58
|
|
?? 1002.0051 0 00:01:03:45
|
|
2500.0001
|
|
6 00A0 TPC 1000.0001 9 0 00:02:44.04
|
|
1300.0001
|
|
?? 1 OOCO NI 0000.7004 3 0 00:04:46.32
|
|
|
|
>>>
|
|
|
|
(The error codes are defined in the troubleshooting
|
|
procedures for each individual device)
|
|
\end{ttfig}
|
|
|
|
The first line indicates the CPU name (KA410-A), the ROM version (V1.0),
|
|
the ROM Status (01 -- the ROM is corrupted if this is anything other than
|
|
01), and the mode of the system exerciser (CU for customer and FS for field
|
|
service mode). The next several lines list information on the devices that
|
|
are exercised by the system exerciser.
|
|
|
|
The first column of the display lists the test number (F,C,B,7,6,1). TESTS 4
|
|
through 1 are option modules and these options may not be installed. They
|
|
are listed in the display only if they are installed. The second column lists
|
|
the device identifier (00B0, 0080, 0010,...). Next is the mnemonic for each
|
|
device (MONO, DZ, MEM,...) followed by the error code (0000.0000) for
|
|
that device (the HDC and TPC devices have additional error codes for each
|
|
drive). After the error code is the number of times the device was tested
|
|
followed by the time of the last pass the exerciser made on that device.
|
|
The time is in the format of days hours:minutes:seconds.hundredths of
|
|
seconds. Question marks identify hard (??) and soft (?) errors. See the
|
|
troubleshooting procedures (\hyperlink{section.2.4}{Paragraph 2.4}) for
|
|
the device that has an error detected with it.
|
|
|
|
\section{Troubleshooting Procedures}
|
|
|
|
Each section below contains troubleshooting information for the device
|
|
indicated. Find the section below with the mnemonic (such as MONO or TPC)
|
|
that you want to troubleshoot. Once the section is located, read through the
|
|
procedures to familiarize yourself with the testing of the device.
|
|
|
|
\subsection{MONO -- Monochrome Video Troubleshooting Procedures (VAXstation 2000 only)}
|
|
|
|
You can troubleshoot the monochrome circuitry on the system module
|
|
in either customer mode or field service mode. Both modes test the
|
|
monochrome circuits the same. This procedure does not troubleshoot the
|
|
video monitor, just the video circuits on the system module.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test on MONO, enter TEST F. The monitor connected to the
|
|
video port blinks white and black several times. This is normal. The results
|
|
of the self-test are displayed when self-test is complete. Any error code
|
|
other than 0000.0001 indicates a fault in the monochrome video circuits.
|
|
You must replace the system module to fix this problem.
|
|
|
|
\subsubsection{System Exerciser}
|
|
|
|
To run the system exerciser, enter TEST 0 for customer mode or TEST 101
|
|
for field service mode. The monitor connected to the video port blinks white
|
|
and black several times while the monochrome circuits are being tested. The
|
|
results of the MONO tests are displayed on the console screen after they are
|
|
tested for the first time, then displayed again after each concurrent testing.
|
|
Any error code other than 0000.0001 indicates a fault in monochrome video
|
|
circuits. You must replace the system module to fix this problem. This
|
|
device is not exercised on the MicroVAX 2000 system since MicroVAX 2000
|
|
does not use video monitors.
|
|
|
|
\subsection{CLK -- Time-of-Year Clock Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the CLK circuitry in either customer mode or field
|
|
service mode. Both modes test the CLK circuits the same.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST E. Any error code other than 0000.0001
|
|
indicates a fault in the CLK circuits. An error code of 0000.0005 indicates that
|
|
the system time is not set. Refer to the operating system software
|
|
documentation to set the time. If any other error code appears in the CLK error
|
|
display, you must replace the system module.
|
|
|
|
The system exerciser does not display the Status of the CLK circuits. The
|
|
CLK circuits are not directly tested but are tested through the testing of
|
|
other circuits.
|
|
|
|
\subsection{NVR -- Non-Volatlle RAM Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the NVR circuitry in either customer mode or field
|
|
service mode. Both modes test the NVR circuits the same.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST D. Any error code other than 0000.0001 in
|
|
dicates a fault in the NVR. An error code of 0000.0005 indicates that the
|
|
battery charge is below the normal voltage level. If the battery is low, allow
|
|
the system to charge the battery for five minutes and then run TEST D
|
|
again. If the error code is still 0000.0005, replace the battery. A charging
|
|
time of 20-25 hours is needed to fully charge the battery. Leaving the system
|
|
powered up charges the battery. If any other error code appears in the
|
|
CLK error display, you must replace the system module.
|
|
|
|
The system exerciser does not display the status of the NVR circuits. The
|
|
NVR circuits are not directly tested but are tested through the testing of
|
|
other circuits.
|
|
|
|
\subsection{DZ -- Serial Line Controller Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the DZ in either customer mode or field service mode.
|
|
The difference between the two modes is that field service mode tests the
|
|
serial line drivers on the system module and customer mode does not.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run customer mode self-test on either the VAXstation 2000 or the
|
|
MicroVAX 2000, enter TEST C. Loopback connectors must not be installed
|
|
when in customer mode. Loopback connectors must, however, be installed
|
|
to run field service mode diagnostics. Any error code other than 0000.0001
|
|
indicates a fault in the DZ controller. You must replace the system module
|
|
to fix the problem. If you are using the diagnostic console device, any error
|
|
code other than 0000.4001 indicates a fault in the DZ controller.
|
|
|
|
\textbf{VAXstation 2000}
|
|
|
|
To run self-test in field service mode on VAXstation 2000, install a loopback
|
|
(p/n 29-24795) on the 25-pin communication port and a loopback (p/n 29-24794)
|
|
on the 9-pin printer port. Enter TEST C. If the error code is not
|
|
0000.0001, check to see if the loopbacks are still connected. Reconnect
|
|
them, if necessary, and test again. Replace the system module if the error
|
|
still exists. Loopbacks cannot be used to test the DZ controller when the
|
|
console device is the diagnostic console with the BCC08 cable since there
|
|
is no loopback for the video port.
|
|
|
|
\textbf{MicroVAX 2000}
|
|
|
|
To run self-test in field service mode on MicroVAX 2000, install a loop
|
|
back (p/n 29-24795) on the 25-pin communication port and install an MMJ
|
|
loopback on both ports 2 and 3. Enter TEST C. If the error code is not
|
|
0000.0001, check to see if the loopbacks are still connected. Reconnect
|
|
them, if necessary, and test again. Replace the system module if the error
|
|
still exists.
|
|
|
|
\subsubsection{System Exerciser}
|
|
|
|
To run the customer mode system exerciser on either the VAXstation 2000
|
|
or the MicroVAX 2000, enter TEST 0. The results are displayed on the video
|
|
screen as the tests are completed.
|
|
|
|
\textbf{VAXstation 2000}
|
|
|
|
To run the field service mode system exerciser on VAXstation 2000, install a
|
|
loopback (p/n 29-24795) on the 25-pin communication port and a loopback
|
|
(p/n 29-24794) on the 9-pin printer port. Enter TEST 101. If you are using the
|
|
diagnostic console device, you will get errors on the DZ line since there is
|
|
no loopback for the video port. Any error code other than 0X00.0001, where
|
|
X is the serial line being used for the console device, indicates a fault in
|
|
the DZ controller. You must replace the system module to fix the problem.
|
|
If the console device is connected to the video port on VAXstation 2000,
|
|
then you will see a 0 (zero) in the X position. If the console device is the
|
|
diagnostic console device with the BCC08 cable on the printer port, then
|
|
you will see a 3 in the X position. If the error code is not 0X00.0001, check
|
|
to see if the loopbacks are still connected. Reconnect them, if necessary,
|
|
and test again. Replace the system module if the error still exists.
|
|
|
|
\textbf{MicroVAX 2000}
|
|
|
|
To run the field service mode system exerciser on MicroVAX 2000, install
|
|
a loopback (p/n 29-24795) on the 25-pin communication port and install an
|
|
MMJ loopback on both ports 2 and 3. Enter TEST 101 or TEST 102. Any
|
|
error code other than 0X00.0001, where X is the serial line being used for
|
|
the console device, indicates a fault in the DZ controller. You must replace
|
|
the system module to fix the problem. With the console device connected to
|
|
port 1 on the MicroVAX 2000, you will see a 0 (zero) in the X position. If the
|
|
error code is not 0X00.0001, check to see if the loopbacks are still connected.
|
|
Reconnect them, if necessary, and test again. Replace the system module
|
|
if the error still exists. If the error still exists after replacing the system
|
|
module, replace the DEC423 converter on the back of the system box.
|
|
|
|
\subsection{MEM -- Memory Troubleshooting Procedures}
|
|
|
|
You can troubleshoot memory in either customer mode or field service
|
|
mode. Both modes test the MEM circuits the same. These procedures are
|
|
for both VAXstation 2000 and MicroVAX 2000.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST B. Any error code other than 000X.0001, where
|
|
X is the size of memory (megabytes) in the system, indicates a fault in the
|
|
memory circuits. The problem could either be with the system module or
|
|
the memory Option module. To determine which module is at fault go to
|
|
\hyperlink{subsubsection.2.5.1.2}{Paragraph 2.5.1.2}.
|
|
|
|
\subsubsection{System Exerciser}
|
|
|
|
To run the system exerciser, enter TEST 0 for customer mode or TEST 101
|
|
for field service mode. \figref{2-9} shows what the MEM system exerciser
|
|
error code indicates. The status portion of the code indicates the number
|
|
of pages tested during the last test pass (1 page = 512 bytes) if there were
|
|
no errors found.
|
|
\newpage
|
|
\begin{ttfig}{Example of MEM System Exerciser Error Code}
|
|
.
|
|
.
|
|
.
|
|
B 0010 MEM 0175.0001 2 0 00:02:03.07
|
|
. | | | |
|
|
. `--' `--'
|
|
. | |
|
|
| `-- Error code. 0001 = GOOD
|
|
|
|
|
`------- Status code. Number of
|
|
pages of memory tested
|
|
when error code is 0001.
|
|
\end{ttfig}
|
|
|
|
An error code of .0001 indicates no errors. If errors were detected during
|
|
the last test pass, the error portion of the code contains the error code.
|
|
\tabref{2-5} lists the MEM system exerciser errors and shows which module
|
|
is causing the error.
|
|
|
|
\begin{tbl}{MEM System Exerciser Error Codes}{l l}
|
|
\textbf{Error Codes} & \textbf{Definition}\\
|
|
\hline
|
|
0001.001F & Compare error on the system module\\
|
|
0002.001F & Compare error on the Option module\\
|
|
0001.002F & Parity error on the system module\\
|
|
0002.002F & Parity error on the Option module\\
|
|
\end{tbl}
|
|
|
|
\subsection{MM -- Memory Management Unit Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the memory management (MM) circuitry in either
|
|
customer mode or field service mode. Both modes test the MM circuits the
|
|
same.
|
|
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST A. Any error code other than 0000.0001
|
|
indicates a fault in the memory managment circuits. You must replace the
|
|
system module to fix the problem.
|
|
|
|
The system exerciser does not display the status of the MM circuits. The
|
|
MM circuits are not directly tested but are tested through the testing of other
|
|
circuits.
|
|
|
|
\subsection{FP -- Floating Point Unit Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the floating point (FP) circuitry in either customer
|
|
mode or field service mode. Both modes test the FP circuits the same.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST 9. Any error code other than 0000.0001 indicates
|
|
a fault in the floating point circuits. You must replace the system module
|
|
to fix the problem.
|
|
|
|
The system exerciser does not display the status of the FP circuits. The FP
|
|
circuits are not directly tested but are tested through the testing of other
|
|
circuits.
|
|
|
|
\subsection{IT -- Interval Timer Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the interval timer (IT) circuitry in either customer
|
|
mode or field service mode. Both modes test the IT circuits the same.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST 8. Any error code other than 0000.0001 indicates
|
|
a fault in the timing circuits. You must replace the system module to fix the
|
|
problem.
|
|
|
|
The system exerciser does not exercise the IT circuits.
|
|
|
|
\subsection{HDC -- Disk Drives and Controller Troubleshooting Procedures}
|
|
|
|
|
|
You can troubleshoot the disk controller and drives using self-test and the
|
|
system exerciser. These diagnostics test the disk controller on the system
|
|
module and also test the drives connected to the controller. There is a maximum
|
|
number of three drives that can be supported in either a VAXstation
|
|
2000 or a MicroVAX 2000. The three drives are labelled DUA0, DUA1, and
|
|
DUA2. DUA0 will always be the hard disk drive (RD) located in the system
|
|
box. DUA0 can be a full-height or a half-height drive. DUA1 will always be
|
|
the hard disk drive (RD) located in the expansion box. DUAI communicates
|
|
to the system module through port B on the expansion adapter; thus allowing
|
|
you to isolate DUA1 during testing, if necessary, without opening the
|
|
system box. DUA2 will always be the half-height floppy disk drive (RX33)
|
|
and will only be located in the system box. If DUA0 is a full-height drive,
|
|
then a floppy disk drive cannot be installed because of lack of space in the
|
|
system box. The disk controller labeis any drive off-line that is not installed.
|
|
It also labeis DUA2 off-line if a floppy diskette is not properly loaded.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test on the HDC, enter TEST 7. Self-test gives a quick status
|
|
of the disk controller on the system module and the drives. You can run
|
|
self-test in either customer mode or field service mode since both modes
|
|
test these devices the same. The error code for the disk controller (HDC in
|
|
the configuration table) contains the test results of the disk controller and
|
|
the status of the three drives. \figref{2-10} shows how the error code is
|
|
broken into five segments: status of DUA2, DUA1, DUA0, tape controller,
|
|
and the error code if a hard error is found. The power-up error code is the
|
|
same as the self-test error code.
|
|
|
|
\begin{ttfig}{HDC Power-up and Self-test Error Code}
|
|
7 0090 0000.0000
|
|
|||| | |
|
|
|||| `--'
|
|
|||| |
|
|
|||| `---> These four digits echo the first four digits
|
|
|||| if a hard error is found on the disk
|
|
|||| controller. Otherwise, 0001 = Good.
|
|
||||
|
|
|||`------> Status of disk controller on system module.
|
|
||| 0 = Good.
|
|
|||
|
|
||`-------> Status code for DUA0, listed in Table 2-6.
|
|
||
|
|
|`--------> Status code for DUA1, listed in Table 2-6.
|
|
|
|
|
`---------> Status code for DUA2, listed in Table 2-6.
|
|
|
|
DUA0 is the hard disk drive in the system box.
|
|
DUA1 is the hard disk drive in the expansion box.
|
|
DUA2 is the floppy drive in the system box.
|
|
\end{ttfig}
|
|
|
|
Each drive has the same set of error codes. These codes are listed in
|
|
\tabref{2-6}. All odd-numbered error codes are soft errors or a status. All
|
|
even-numbered error codes (including A and F) are hard errors. The last four
|
|
digits of the error code repeat the first four digits if a hard error is found on
|
|
the disk controller. Otherwise, the last four digits contain 0001 to indicate
|
|
no errors or soft errors.
|
|
|
|
\begin{tbl}{Power-up and Self-test Error Codes for each Dlsk Drive}{p{0.2\textwidth} p{0.75\textwidth}}
|
|
\textbf{Error Codes} & \textbf{Description of error codes for each disk drive}\\
|
|
\hline
|
|
1 & Good -- No error for this drive.\\
|
|
|
|
2 & Drive select error. Disk controller or the drive failed. Replace the system
|
|
module first. Replace the drive if the problem is not fixed after replacing
|
|
the system modile. \\
|
|
|
|
3 & Read during read test error. The disk or diskette may not be formatted. Run
|
|
the disk verifier to chekc out the disk. Copy the disk fata onto another disk
|
|
or to another system over the net if you have to reformat the drive. \\
|
|
|
|
4 & Read after write error. Drive failed. Replace the drive first. Replace the
|
|
system module of the problem is not fixed after replacing the drive. \\
|
|
|
|
5 & Invalid UIB (DUA0 and DUA1 only). Disk needs formatting or the disk is
|
|
not a Digital disk. Run the disk verifier to check out the disk. Copy the
|
|
disk data onto another disk or to another system over the net if you have
|
|
to reformat the drive. \\
|
|
|
|
6 & Drive failed to restore. Drive failed. Replace the drive first. Replace the
|
|
system module if the problem is not fixed after replacing the drive. \\
|
|
|
|
7 & Off-line — No drive installed, no floppy diskette loaded in DUA2, or DUA1
|
|
(in expansion box) is not turned on. \\
|
|
|
|
8 & Drive not done error. Drive failed. Replace the drive first. Replace the
|
|
system module if the problem is not fixed after replacing the drive. \\
|
|
|
|
9 & Invalid Status from controller. Disk controller or diskette failed. If DUA0
|
|
or DUA1, replace the system module first then replace the disk drive if the
|
|
problem is not fixed after replacing the system module. If DUA2, replace
|
|
the floppy diskette first or save the data on it and reformat it. If DUA2 and
|
|
the floppy diskette is not the problem, replace the system module and then
|
|
replace the floppy disk drive if replacing the system module did not fix the
|
|
problem. \\
|
|
|
|
A & Drive select timeout error. Drive failed. Replace the drive first. Replace
|
|
the system module if the problem is not fixed after replacing the drive. \\
|
|
|
|
F & Untested -- Drive was not tested because of a hard error found on the disk
|
|
controller. For example, FFF8.FFF8 indicates an error on the disk controller
|
|
and no drives were tested. Replace the system module. \\
|
|
\hline
|
|
\end{tbl}
|
|
|
|
If any error (except 7 and F) appears for any drive, check the drive for
|
|
power and check the cables for a good connection. If the error still exists,
|
|
the problem is either in the drive, in the cables, in the system module, or in
|
|
the disk interface module located in the expansion adapter. If, for example,
|
|
you replace one of the disks to fix an error code and the error still exists,'
|
|
replace the system module. If the system module does not fix the problem
|
|
replace the disk interface module.
|
|
|
|
\subsubsection{System Exerciser}
|
|
|
|
Start the system exerciser by entering TEST 0 for customer mode or install
|
|
the 25-pin loopback on the communications port and enter TEST 101 for
|
|
field service mode. The customer mode system exerciser does not exercise
|
|
the disks as thoroughly as the field service exerciser. The field service
|
|
system exerciser performs a complete read/write test on all drives and also
|
|
performs a data transfer test between the disk controller and one of the
|
|
drives.
|
|
|
|
The results of the system exerciser are displayed on the screen after the
|
|
first test pass of each device tested and again after all devices have been
|
|
run concurrently. \figref{2-11} shows the system exerciser display for the
|
|
disk controller (HDC). There is one line for the controller Status and one
|
|
line for each drive connected to the controller. A drive that is not installed
|
|
or is off-line is not listed in the display. For example, no diskette in DUA2
|
|
or an unformatted diskette in DUA2 labeis DUA2 as off-line and no display
|
|
for DUA2 is listed. If there are two question marks on the controllers line,
|
|
replace the system module. If there is a single question mark on the drive's
|
|
line, there is a soft error in the drive and the drive may operate normally.
|
|
Two question marks on the drive's line indicate a hard error in the drive
|
|
or an error in the controller. You must replace one or both to fix the error.
|
|
Two question marks for DUA2 may also indicate bad media on the floppy
|
|
diskette.
|
|
|
|
\begin{ttfig}{Example of System Exerciser Display for the Disk Controller}
|
|
.
|
|
.
|
|
.
|
|
7 0090 HDC 1000.0001 2 0 00:02:09.47
|
|
0700.0001
|
|
1700.0001
|
|
2500.0001
|
|
.
|
|
.
|
|
.
|
|
\end{ttfig}
|
|
|
|
\tabref{2-7} lists the erorr codes for the disk controller's line and \tabref{2-8}
|
|
lists the error codes for the drives.
|
|
|
|
\begin{tbl}{HDC Disk Controller System Exerciser Error Codes}{p{0.1\textwidth} p{0.3\textwidth} p{0.5\textwidth}}
|
|
\textbf{Error Codes} & \textbf{Possible Cause} & \textbf{Corrective Action}\\
|
|
\hline
|
|
|
|
X000.0001 & The X indicates the drive used for the data transfer test &
|
|
0 = DUA0, 1 = DUA1, 2 = DUA2, and F = no data transfer test was done. \\
|
|
|
|
0X00.0001 & Data transfer error if X is anything other than zero &
|
|
Replace the system module. If the error still exists after replacing the system module, replace the
|
|
drive that was used for the data transfer test. Always replace the drive's device electronics board
|
|
(hard disk drives only) before replacing the whole drive. \\
|
|
|
|
00XX.0001 & The XX indicates the number of errors detected during the data transfer test.
|
|
Make note of the drive used for the data transfer test. &
|
|
Run the exerciser again. Was the same drive used for the transfer test?
|
|
|
|
If yes, and the number of transfer errors are the same (or dose to the same), replace system module.
|
|
Replace the drive that was used for the data transfer test if replacing the system module did
|
|
not fix the problem.
|
|
|
|
If no, and the number of transfer errors are zero, replace the drive that got errors during the data
|
|
transfer test. Always replace the dxive's device electronics board (hard disk drives only) before
|
|
replacing the whole drive. \\
|
|
|
|
0000.XXX1 & Controller error. &
|
|
If XXX is anything other than 000 (three zeros), replace the system module.\\
|
|
|
|
\end{tbl}
|
|
|
|
\begin{tbl}{HDC Dlsk Drive System Exerciser Error Codes}{p{0.1\textwidth} p{0.25\textwidth} p{0.55\textwidth}}
|
|
\textbf{Error Codes} & \textbf{Possible Cause} & \textbf{Corrective Action}\\
|
|
\hline
|
|
|
|
X000.0001 & The X position indicates the drive that this error code is for. &
|
|
0 = DUA0, 1 = DUA1, and 2 - DUA2.
|
|
\\
|
|
0X00.0001 & The X position indicates the drive Status. &
|
|
The X position indicates drive status as listed below.
|
|
|
|
DUA0 and DUA1:\newline
|
|
\hspace*{1em}7 writeable, formatted, UIB and RCT ok\newline
|
|
\hspace*{1em}5 writeable, formatted, no UIB and RCT\newline
|
|
\hspace*{1em}4 writeable, unformatted, no UIB and RCT\newline
|
|
\hspace*{1em}3 non-writeable, formatted, UIB and RCT ok\newline
|
|
\hspace*{1em}1 non-writeable, formatted, no UIB and RCT\newline
|
|
\hspace*{1em}0 non-writeable, unformatted, no UIB and RCT
|
|
|
|
DUA2:\newline
|
|
\hspace*{1em}5 writeable and formatted\newline
|
|
\hspace*{1em}4 writeable and unformatted\newline
|
|
\hspace*{1em}1 non-writeable and formatted\newline
|
|
\hspace*{1em}0 non-writeable and unformatted
|
|
\\
|
|
00XX.0001 & The XX position indicates the drive error count. 00 indicates no error. &
|
|
Run the exerciser again. Note the error count for the failing drive after each pass. If the count stays
|
|
the same or increases, replace the failing drive. If the error still exists after replacing the drive,
|
|
replace the system module. Always replace the drive's device electronics board (hard disk drives
|
|
only) before replacing the whole drive.
|
|
\\
|
|
0000.XXX1 & The XXX position indicates the error codes for the drive. 000 indicates no error. &
|
|
If anything other than zeros (0001), replace the system module. Replace the drive if replacing the
|
|
system module did not fix the problem. Always replace the drive's device electronics board (hard
|
|
disk drives only) before replacing the whole drive.
|
|
\\
|
|
\end{tbl}
|
|
\newpage
|
|
|
|
\subsubsection{Troubleshooting the Hard Disk Drive Expansion Box}
|
|
|
|
Troubleshoot the hard disk in the expansion box (DUA1) using self-test and
|
|
the system exerciser. However, if the diagnostic tests indicate an error on
|
|
DUA1, perform the steps in the following procedure.
|
|
|
|
\begin{enumerate}
|
|
\item Check to make sure the expansion box has power to it and it is switched on.
|
|
|
|
\item Check to make sure the hard disk cable is properly connected to port
|
|
B on the expansion adapter and the back of the expansion box.
|
|
|
|
\item Run the tests again and if the status code shows DUA1 to be off-line,
|
|
troubleshoot the power supply in the expansion box.
|
|
|
|
\item Disconnect the cable from port B on the expansion adapter and run
|
|
self-test (TEST 6). If any status other than the off-line indication (7) or
|
|
the not tested indication (F) shows up in the status code for DUA1, then
|
|
replace the disk controller on the system module.
|
|
|
|
\item If the status code does show that DUA1 is off-line after disconnecting
|
|
it from port B, check the drive select jumpers on DUA1 for proper
|
|
positioning. Refer to \hyperlink{subsubsection.2.4.9.4}{Paragraph 2.4.9.4}
|
|
below for proper drive select jumper settings.
|
|
|
|
\item If the drive select jumper is set properly, replace DUAl in the disk
|
|
expansion box. Always replace the drive's device electronics board
|
|
before replacing the whole drive.
|
|
\end{enumerate}
|
|
|
|
\subsubsection{Drive Select Jumper Settings on Disk Drives}
|
|
|
|
DUA0 -- Refer to \figref{2-12} to set the drive select jumper on an RD32 in
|
|
the system box. Refer to \figref{2-13} to set the drive select jumper on an
|
|
RD53 in the system box.
|
|
|
|
DUA1 -- Refer to \figref{2-13} to set the drive select jumper on an RD53 in
|
|
the expansion box.
|
|
|
|
DUA2 -- Refer to \figref{2-14} to set the drive select jumper on an RX33 in
|
|
the system box.
|
|
|
|
\fig[0.6]{MA-0131-87}{RD32 Drive Select Jumper Setting for DUA0}
|
|
\fig[0.6]{SHR-0126-85}{RD53 Drive Select Jumper Setting for DUA0 and DUA1}
|
|
|
|
\fig[0.7]{SHR-0045-86}{RX33 Drive Select Jumper Setting for DUA2}
|
|
|
|
\subsection{TPC -- Tape Drive Controller Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the tape drive Controller on the system module and
|
|
the tape drive controller in the expansion box using self-test or the system
|
|
exerciser. The tape drive expansion box has an internal self-test to
|
|
troubleshoot the TK50 tape drive as described in \hyperlink{subsubsection.2.4.10.3}{Paragraph 2.4.10.3}.
|
|
|
|
These troubleshooting procedures assume that only one tape expansion box
|
|
is connected to the tape port (port A) on the expansion adapter. Although
|
|
the diagnostic firmware located in ROM supports up to seven devices on
|
|
port A of the expansion adapter, we will only cover how to troubleshoot one
|
|
tape expansion box since the VMS and ULTRIX operating systems support
|
|
only one tape expansion box on either system. Also, the tape expansion
|
|
box must be configured for ID address 1 on the tape port.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST 6. Self-test gives a quick status of the tape
|
|
controller on the system module and also the tape drive expansion box
|
|
connected to the tape controller via port A of the expansion adapter. You
|
|
can run self-test in either customer mode or field Service mode since both
|
|
modes test these devices the same. Enter TEST 50 to see the results of the
|
|
self-test. The TPC error code contains the test results of the tape controller
|
|
on the system module and the tape drives connected to port A on the
|
|
expansion adapter. \figref{2-15} shows how the TPC error code is broken
|
|
into five segments: ID addresses of devices connected to the tape port,
|
|
ID addresses of the devices that tested successfully, two possible cause
|
|
indicators, and a status of the tape controller.
|
|
|
|
\begin{ttfig}{TPC Power-up and Self-test Error Code}
|
|
6 00A0 0000.0000
|
|
|||| ||||
|
|
`|`| ||`|
|
|
| | || `--> Status of tape controller on system module.
|
|
| | || 01 = Good.
|
|
| | ||
|
|
| | |`----> Possible cause indicator.
|
|
| | | 0 = Good.
|
|
| | | 1 = Error most likely on system module.
|
|
| | | 2 = Error most likely in expansion box.
|
|
| | | 3 = Error could be in either location.
|
|
| | `-----> Possible cause indicator.
|
|
| | 0 = Good.
|
|
| | 1 = Retest TPC again.
|
|
| | 2 = Error most likely in expansion box.
|
|
| | 3 = Combination of 1 and 2.
|
|
| | 4 = DMA and interrupts not tested.
|
|
| | 5 = Combination of 1 and 4.
|
|
| | 6 = Combination of 2 and 4.
|
|
| | 7 = Combination of 1, 2, and 4.
|
|
| |
|
|
| `-------> Status of the tape expansion box. The
|
|
| ID address of the expansion box is
|
|
| displayed here if it tested
|
|
| diccessfully. These two digits should
|
|
| be the same as the first two digits.
|
|
| 00 = No box connected to port A or
|
|
| no box tested successfully.
|
|
| 02 = ID Address 1
|
|
| 04 = ID Address 2
|
|
| 08 = ID Address 3
|
|
| 10 = ID Address 4
|
|
| 20 = ID Address 5
|
|
| 40 = ID Address 6
|
|
| 80 = ID Address 7
|
|
|
|
|
`---------> ID Address (shown above) of the tape
|
|
expansion box that is connected to
|
|
port A.
|
|
\end{ttfig}
|
|
|
|
A status code of 0000.4001 indicates a good status for the tape controller
|
|
when no devices are connected to port A. If there is a tape expansion box
|
|
connected to port A and the status code is 0000.4001, then the controller
|
|
does not recognize it or it is not powered up.
|
|
|
|
If the second two digits of the status code shown in \figref{2-15} (good
|
|
devices) do not match the first two digits (connected devices), then there
|
|
is a communication problem between the tape expansion box and the system.
|
|
Disconnect the cable from port A on the expansion adapter and run
|
|
self-test again. If the status code for TPC now contains anything other than
|
|
0000.4001, replace the system module. Otherwise, if the status code is
|
|
0000.4001, reconnect the cable to port A and make sure the tape expan
|
|
sion box is powered up. Run self-test again. If the status code for TPC
|
|
is not 0202.0001 after reconnecting the cable, run the system exerciser to
|
|
thoroughly test the tape controller and the tape expansion box. If the error
|
|
code is 0202.0001 after reconnecting the tape expansion box, the tape Con
|
|
troller and the expansion tape box are operating properly. Note that there
|
|
may be more than one tape expansion box on systems that run an operating
|
|
system other than VMS or ULTRIX. This means that the status code may be
|
|
0606.0001 for two devices at ID address 1 and 2 or FEFE.0001 for all seven
|
|
devices connected to the tape port. However, if the system does use VMS
|
|
or ULTRIX, the tape expansion box at ID address 1 is the only device VMS
|
|
and ULTRIX can communicate with.
|
|
|
|
\subsubsection{System Exerciser}
|
|
|
|
Start the system exerciser by entering TEST 0 for customer mode or install
|
|
the 25-pin loopback on the communications port, load the COMPACTape
|
|
cartridge with the special-key into the TK50, and enter TEST 101 for field
|
|
Service mode. The customer mode system exerciser does not exercise the
|
|
tape controller as thoroughly as the field Service exerciser. The field Service
|
|
mode system exerciser performs a complete read/write test on the TK50
|
|
tape drive and also performs a data transfer test while the customer mode
|
|
system exerciser does not test the TK50 tape drive at all.
|
|
|
|
The system exerciser runs a first pass test on MONO (VAXstation only), DZ,
|
|
MEM, and HDC before it runs the first pass test on the TPC. The first pass
|
|
test on the TPC tests the tape controller on the system module and checks
|
|
the tape port for the presence of a tape expansion box only if the tape Con
|
|
troller is operating properly. If the tape controller on the system module
|
|
tests bad, the error code for the tape controller lists an error and the tape
|
|
port is not checked for the presence of the tape expansion box. The first
|
|
pass test of the TPC does not perform any diagnostics or data transfer tests
|
|
on the tape expansion box. The first pass test only checks whether or not the
|
|
tape expansion box is there and whether or not it can communicate over the
|
|
tape port to the tape controller. Complete data transfer and read/write (field
|
|
Service mode only) testing is done on subsequent test passes. For example,
|
|
in field Service mode with the Special keyed COMPACTape cartridge
|
|
installed, the error code for the tape expansion box shows that the TK50 is
|
|
not writeable (1100.0001) during the first pass. However, the second pass
|
|
shows that the TK50 is writeable (1300.0001) as long as the cartridge has a
|
|
good Special key on it and the tape expansion box is operating properly.
|
|
So you must wait for the system exerciser to complete at least two passes
|
|
on the TPC to see if the tape expansion box is operating properly.
|
|
|
|
\figref{2-16} shows the system exerciser display for the TPC. There is one
|
|
line for the status of the tape controller on the system module and one line
|
|
for each tape expansion box connected to the tape port if it is powered
|
|
up. The status of the tape controller is next to the TPC mnemonic (first
|
|
line) and the status of the tape expansion box is listed under the status of
|
|
the controller. An easy way of determining if any errors are detected is by
|
|
looking for the question marks in the left column. If there are any question
|
|
marks on the tape controllers status line, the tape controller is faulty and
|
|
the error code identifies the problem. Refer to \tabref{2-9} to decifer the tape
|
|
controllers error code and determine how to fix the problem. If there are
|
|
any question marks on the tape expansion box's status line, the problem
|
|
could be in either the tape expansion box, the tape expansion box cable, or
|
|
the tape controller on the system module. An error that is listed in the tape
|
|
expansion box's error code may be a data transfer error and thus does not
|
|
isolate the problem to the tape expansion box; it may still be in the tape
|
|
controller on the system module. Refer to \tabref{2-10} to decifer the tape
|
|
expansion box's error code and determine how to fix the problem.
|
|
|
|
If errors are detected with the TPC, disconnect the tape expansion box cable
|
|
from port A on the expansion adapter and run the test again. This procedure
|
|
isolates the tape expansion box from the system box. If any errors appear
|
|
in the tape controllers error code, the problem is with the tape controller
|
|
and the system module must be replaced. Otherwise, the error is in the
|
|
expansion box and you must run the internal self-test on the expansion box
|
|
as described below.
|
|
|
|
\begin{ttfig}{Example of System Exerciser Display for the Tape Controller}
|
|
.
|
|
.
|
|
.
|
|
6 00A0 TPC 1000.0001 2 0 00:03:18.26
|
|
1300.0001
|
|
.
|
|
.
|
|
.
|
|
\end{ttfig}
|
|
|
|
\newpage
|
|
|
|
\tabref{2-9} lists the system exerciser enor codes for the controller's error line
|
|
and \tabref{2-10} lists the system exerciser error codes for the tape drives error
|
|
line.
|
|
|
|
\begin{tbl}{TPC Tape Controller System Exerciser Error Codes}{p{0.2\textwidth} p{0.2\textwidth} p{0.5\textwidth}}
|
|
\textbf{Error Codes} & \textbf{Possible Cause} & \textbf{Corrective Action}\\
|
|
\hline
|
|
|
|
X000.0001 & This error code indicates no Controller error. The X indicates
|
|
the transfer test drive number. &
|
|
The X position indicates the tape drive that was used for data transfer testing. This number should
|
|
be 1 if a tape expansion box is connected to the system and it is powered up. This number should be
|
|
8 if no tape expansion box is connected or if it is turned off. An F will always be in this position
|
|
during the first pass of the exerciser. If the P is still in this position after the first pass is complete, a
|
|
fatal error is detected in the tape controller on the system module and the tape expansion box is not
|
|
tested.
|
|
\\
|
|
|
|
0X00.0001 & The X indicates a data transfer error if X is anything other than zero. &
|
|
Replace the system module. If the error still exists, replace the TK50 tape drive.
|
|
Then if the error code still exists, replace tbe TZK50 controller board.
|
|
\\
|
|
00XX.0001 & The XX indicates the number of data transfer errors detected.
|
|
Make a note of the tape drive used for the data transfer test. &
|
|
Run the exerciser again. Was the same drive used for the transfer test? If yes, and the number of
|
|
transfer errors are the same (or close to the same), replace the system module. If no, and the number
|
|
of transfer errors are zero or considerably less than before, replace the TK50 drive that was originally
|
|
used for the transfer test. If the error code still exists, replace the TZK50 controller board.
|
|
\\
|
|
0000.XXX1 & Controller error if any X is anything other than zero. &
|
|
Replace the system module.
|
|
\\
|
|
|
|
\end{tbl}
|
|
|
|
|
|
\begin{tbl}{Tape Drive Expansion Box System Exerciser Error Codes}{p{0.2\textwidth} p{0.2\textwidth} p{0.5\textwidth}}
|
|
\textbf{Error Codes} & \textbf{Possible Cause} & \textbf{Corrective Action}\\
|
|
\hline
|
|
|
|
X000.0001 & The X indicates the device ID address of tape expansion box. &
|
|
This device ID address can be 1, 2, 3, 4, 5, 6, or 7. It should normally be 1 unless the device ID address
|
|
jumpers (Pl, P2, P3) on the TZK50 controller board have been changed. It must never be 0. If a 0 is in
|
|
this position, the device ID address jumpers are set to zero and they must be reset to another ID. The
|
|
ID address must be 1 for systems running VMS or ULTRIX.
|
|
\\
|
|
0X00.0001 & The X indicates the tape cartridge status. &
|
|
The X position indicates whether or not the device on the tape port has removeable or non-removeable
|
|
media and also whether or not the device is writeable. 1 = removeable media, 2 = writeable, and 3
|
|
= removeable media and it is writeable. This digit should be a 1 or a 3 since the TK50 has removeable
|
|
media. This digit should be a 1 in customer mode and a 3 in field Service mode if the special-keyed
|
|
cartridge is installed and loaded in the TK50. Note that this digit can never be a 3 in field Service mode
|
|
until a second pass test is done on the TPC since the system exerciser does not do a write test on the first
|
|
pass.
|
|
\\
|
|
00XX.0001 & The XX indicates the drive error count during the data transfer test. 00 indicates no error. &
|
|
The error may be in the TZK50 controller board, the TK50 tape drive, or the tape controller on the
|
|
system module. Run the exerciser again but with another tape expansion box, if possible, to determine
|
|
if the error is on the tape controller or in the tape expansion box you removed. If the data
|
|
transfer error still appears after replacing the tape expansion box, replace the system module.
|
|
Otherwise, troubleshoot the tape expansion box as shown in \hyperlink{subsubsection.2.4.10.3}{Paragraph 2.4.10.3}
|
|
below. If you do not have an other tape expansion box to swap out, replace the following FRUs one at a time
|
|
and run the exerciser after each one is replaced until there are no more transfer errors. First, TZK50
|
|
controller board; second, TK50 tape drive; third, the system module. Remember that the TK50 tape drive is not
|
|
tested in customer mode and is also not tested in field service mode if the special-keyed tape cartridge is not
|
|
loaded in the TK50 tape drive.
|
|
\\
|
|
\end{tbl}
|
|
|
|
\begin{tblcont}{Tape Drive Expansion Box System Exerciser Error Codes}{p{0.2\textwidth} p{0.2\textwidth} p{0.5\textwidth}}
|
|
\textbf{Error Codes} & \textbf{Possible Cause} & \textbf{Corrective Action}\\
|
|
\hline
|
|
0000.XXX1 & The XXX indicates the error codes. 000 indicates no errors. &
|
|
If anything other than zeros (.0001) appear, Run the exerdser again but with another tape expansion
|
|
box, if possible, to determine if the error is on the tape controller or in the tape expansion box you
|
|
removed. If the error still appears after replacing the tape expansion box, replace the system module.
|
|
Otherwise, troubleshoot tne tape expansion box as shown in \hyperlink{subsubsection.2.4.10.3}{Paragraph 2.4.10.3}
|
|
below. If you do not have another tape expansion box to swap out, replace the following FRUs one at a time and run the
|
|
exerciser after each one is replaced until there are no more transfer errors. First, TZK50 controller
|
|
board; second, TK50 tape drive; third, the system module. Remember that the TK50 tape drive is not
|
|
tested in customer mode and is also not tested in field service mode if the special-keyed tape cartridge
|
|
is not loaded in the TK50 tape drive.
|
|
\\
|
|
\end{tblcont}
|
|
|
|
\subsubsection{Troubleshooting the Tape Expansion Box}
|
|
|
|
If the results for the TPC indicate a problem in the tape expansion box, the
|
|
problem could be the TK50 tape drive, the TZK50 controller board, or the
|
|
power supply. The TK50 tape drive performs an internal self-test every time
|
|
the tape expansion box is powered up. The TZK50 controller also performs
|
|
an internal self-test at power up. To do an in-depth self-test on the TK50
|
|
tape drive and the TZK50 controller board, follow the procedure below. Do
|
|
each step indicated until you find and fix the problem.
|
|
|
|
\begin{enumerate}
|
|
|
|
\item Remove the tape drive expansion box cover.
|
|
|
|
\item Check all cables to make sure they are connected properly. Remove the
|
|
shield to check the cables on the back of the drive. Note that there are
|
|
two power cables connected to the resistor load board.
|
|
|
|
\item Check the jumpers on the TZK50 controller board for proper installation.
|
|
Refer to \figref{2-17} for jumper locations and tape port ID address
|
|
confirmation. \figref{2-17} shows the controller board set for ID
|
|
address 1, with parity checking enabled, and internal diagnostics disabled.
|
|
Make sure the three ID address jumpers (Pl, P2, and P3) are set
|
|
to ID address 1. Jumper P4 is the parity checking jumper and must be
|
|
installed for normal operation. Jumper P5 is the diagnostic jumper and
|
|
must not be installed for normal operation. Note the position of the
|
|
spare jumper(s). Spare jumpers should be stored across P5 and one of
|
|
the spare posts.
|
|
|
|
\item Check the three resistor network packs (Z7, Z6, and Z5) to make sure
|
|
they are installed properly. If this expansion box is the only box
|
|
connected to the tape port, these resistor network packs must be installed
|
|
on this board. If this expansion box is not the only box connected to the
|
|
tape port, then make sure the last box in the chain contains these
|
|
resistor network packs and all other boxes in the chain have their resistor
|
|
network packs removed.
|
|
|
|
\item Plug in the power cord and switch on power to the expansion box.
|
|
|
|
\item If the LED on the TZK50 controller board and on the TK50 tape drive
|
|
do not light when power is first turned on or the fan does not turn,
|
|
troubleshoot the power supply (\hyperlink{subsection.2.4.13}{Paragraph 2.4.13}).
|
|
|
|
\item Watch the red light on the TK50 tape drive. It should shut off after five
|
|
to six seconds after power up if no tape is installed. If it starts flashing,
|
|
replace the TK50 tape drive. When a tape is installed, the red light stays
|
|
lit.
|
|
|
|
\item Look at the LED on the TZK50 controller board. It turns on at power
|
|
up, then turns off after two seconds. It must stay off once it turns off.
|
|
If it does not stay off, replace the TZK50 controller board.
|
|
|
|
\item Insert and load a blank COMPACTape cartridge into the TK50 tape
|
|
drive. Do not use the special-keyed cartridge from the kit or a cartridge
|
|
that has good data, because the next few steps will erase the special
|
|
key and the data on the cartridge. If you must use the special-keyed
|
|
cartridge, reload the special key onto the cartridge using TEST 73 after
|
|
you complete this procedure.
|
|
|
|
\item Switch off power to the expansion box.
|
|
|
|
\item Remove a spare jumper and install it onto P5. If there are two spare
|
|
jumpers then both must be removed from their storage positions so one
|
|
of them can be installed onto P5.
|
|
|
|
\item Switch on the power switch.
|
|
|
|
\item Wait about one minute for the test to finish. If the LED on the TZK50
|
|
controller board starts flashing during or at the end of the test, replace
|
|
the TK50 tape drive. If the LED is on steady, replace the TZK50 Con
|
|
troller board. If the LED is off, the TZK50 controller board and the TK50
|
|
tape drive are operating properly. Note that the LED comes on again
|
|
at the end of the test for about two seconds to indicate that the testing
|
|
cycle has completed and is starting over again. The test will continue
|
|
to cycle until the P5 diagnostic jumper is removed or power is switched
|
|
off.
|
|
|
|
\newpage
|
|
\fig{MA-0158-87}{TZK50 Controller Board Jumper Locations}
|
|
\newpage
|
|
|
|
\item Replace the faulty component, if any, and retest.
|
|
|
|
\item Set up the jumpers on the TZK50 controller board for normal operation.
|
|
Spare jumpers must be stored across P5 and one of the spare posts.
|
|
|
|
\item This concludes the troubleshooting procedures for the tape expansion
|
|
box.
|
|
|
|
\end{enumerate}
|
|
|
|
\subsection{SYS -- Interrupt Controller and ThinWire Ethernet ID ROM Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the interrupt controller and ThinWire Ethernet ID
|
|
ROM (SYS) in either customer mode or field service mode. Both modes
|
|
test these circuits the same.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST 5. Any error code other than 0000.0001 or
|
|
0000.0100 indicates a fault in the interrupt Controller or the ThinWire Ether
|
|
net ID ROM on the system module. The 0000.0100 error code indicates that
|
|
the keyboard is disconnected from the VAXstation 2000 systems. Replace
|
|
just the ThinWire Ethernet ID ROM on the system module to fix an error
|
|
code of 0000.0004. Replace the system module to fix any other error code.
|
|
The replacement procedure for the system module instructs you to remove
|
|
the Thinwire Ethernet ID ROM from the system module being removed and
|
|
install it onto the new system module. If the ThinWire Ethernet ID ROM
|
|
has been replaced for an error code of 0000.0004 and the same error code
|
|
of 0000.0004 reappears when you retest, replace the system module instead
|
|
of just the ThinWire Ethernet ID ROM.
|
|
|
|
The system exerciser does not display the status of the SYS circuits. The
|
|
SYS circuits are not directly tested but are tested through the testing of other
|
|
circuits.
|
|
|
|
\newpage
|
|
|
|
\subsection{NI -- ThinWire Ethernet Network Option Troubleshooting Procedures}
|
|
|
|
You can troubleshoot the ThinWire Ethernet network option (NI) in either
|
|
customer mode or field service mode. Both modes of self-test test the network
|
|
option the same. The field service mode of the system exerciser does
|
|
a more in-depth testing of the option. To troubleshoot the network option,
|
|
run self-test (TEST 1) or run the system exerciser (TEST 0 for customer mode
|
|
or TEST 101 for field service mode).
|
|
|
|
Self-test and the system exerciser test the network interconnect module,
|
|
the ThinWire transceiver circuits on the system module, and also perform
|
|
a loopback function on the ThinWire cable. All tests fail with an error
|
|
code of 0000.7004 if the ThinWire cable is not connected to the back of the
|
|
System box. An error code of 0000.7008 indicates the ThinWire cable is
|
|
not terminated properly. Check the ThinWire cable first if any error code
|
|
has a number seven in the fifth position (0000.7000). The seven in the fifth
|
|
Position indicates a loopback error, but it does not exclude a problem on the
|
|
network option inside the system box. An error code of 0000.0001 indicates
|
|
no error and the network option is operational.
|
|
|
|
\subsubsection{Self-test}
|
|
|
|
To run self-test, enter TEST 1. Any error code other than 0000.0001 indicates
|
|
a fault in either the network interconnect module or on the ThinWire
|
|
Ethernet cable. Note that positions 3 and 4 (00XX.0001) in the error code
|
|
indicate the number of retries over the Ethernet cable before a success. If
|
|
the error code is not 0000.0001, check the ThinWire Ethernet cable on the
|
|
back of the system for proper connections and terminators. Reconnect the
|
|
Thinwire cable and terminators, if disconnected, and test again. If the error
|
|
code is 0000.7000 or above (for example, 0000.7001 or higher), disconnect
|
|
the ThinWire T connector from the back of the system and install the T con
|
|
nector with terminators from the service kit. Run the test again. If the error
|
|
code is 0000.0001 after installing the T connector with both terminators, the
|
|
problem is on the ThinWire Ethernet cable. Otherwise, if the error code
|
|
is anything other than 0000.0001, replace the network interconnect module
|
|
and test again with the T connector and both terminators installed. If the
|
|
error code is still not 0000.0001 after repladng the network interconnect
|
|
module, replace the system module.
|
|
|
|
\subsubsection{System Exerciser}
|
|
|
|
To run the system exerciser, enter TEST 0 for customer mode or TEST 101
|
|
for field service mode. Field service mode does a more in-depth test of
|
|
the circuits. Any error code other than 0000.0001 indicates a fault in the
|
|
network interconnect module or on the system module. Unlike the self-test
|
|
for the network Option, the system exerciser does not do any testing over
|
|
the ThinWire Ethernet cable. It only tests the internal circuitry. If the error
|
|
code is not 0000.0001, replace the network interconnect module. If the error
|
|
code is still not 0000.0001 after replacing the network interconnect module,
|
|
replace the system module.
|
|
|
|
\subsection{Power Supply Troubleshooting Procedures}
|
|
|
|
Follow the flowchart in \figref{2-18} if a problem with the power supply in
|
|
either the system box, hard disk expansion box, or tape drive expansion
|
|
box exists. The flowchart is designed to troubleshoot the power supply in
|
|
any of the three boxes.
|
|
|
|
\fig[0.6]{MA-0066-87}{Flowchart for Troubleshooting the Power Supply}
|
|
|
|
\fig{MA-0156-87}{Power Connectors Pin Voltages}
|
|
|
|
\newpage
|
|
|
|
\subsection{VR260 Monochrome Monitor Troubleshooting Procedures}
|
|
|
|
\tabref{2-11} lists some Symptoms of common problems with the VR260.
|
|
When troubleshooting the VR260, follow the suggested corrective actions
|
|
in the order listed.
|
|
|
|
\begin{tbl}{VR260 Troubleshooting Table}{p{0.3\textwidth} p{0.6\textwidth}}
|
|
\textbf{Symptom} & \textbf{Corrective Action} \\
|
|
\hline
|
|
|
|
No LED; blank screen. &
|
|
Check the power cord connection.
|
|
|
|
\vspace*{0.8em}
|
|
Check the 120/240 Vac setting.
|
|
|
|
\vspace*{0.8em}
|
|
Check the fuse.
|
|
|
|
\vspace*{0.8em}
|
|
Remove the rear bulkhead assembly and check the connection to the transformer assembly.
|
|
|
|
\vspace*{0.8em}
|
|
Check the deflection board connections.
|
|
|
|
\vspace*{0.8em}
|
|
Replace the deflection board connections.
|
|
\\
|
|
Flashing LED. &
|
|
Check the deflection board connections, including the chassis ground.
|
|
|
|
\vspace*{0.8em}
|
|
Make sure the high-voltage anode lead has a good connection with the CRT.
|
|
|
|
\vspace*{0.8em}
|
|
Replace the deflection board.
|
|
\\
|
|
Compressed raster; no video display. &
|
|
Make sure the monitor cable is connected between the system and the monitor.
|
|
|
|
\vspace*{0.8em}
|
|
Adjust the contrast and brightness adjustments.
|
|
|
|
\vspace*{0.8em}
|
|
Run the monochrome video diagnostics (TEST F). If a failure is indicated,
|
|
replace the System module in the system box before proceeding with troubleshooting the VR260.
|
|
|
|
\vspace*{0.8em}
|
|
Remove the rear bulkhead assembly and check the cable connections to the video amp board.
|
|
|
|
\vspace*{0.8em}
|
|
Remove the video amp board and check the CRT pin connections.
|
|
|
|
\vspace*{0.8em}
|
|
Replace the video amp board.
|
|
\\
|
|
Raster; no video display. &
|
|
Run the monochrome video diagnostics (TEST F). If a failure
|
|
is indicated, replace the system module in the System
|
|
box before proceeding with troubleshooting the VR260.
|
|
|
|
\vspace*{0.8em}
|
|
Ensure good CRT connections.
|
|
|
|
\vspace*{0.8em}
|
|
Replace the video amp board.
|
|
\\
|
|
\end{tbl}
|
|
|
|
\begin{tblcont}{VR260 Troubleshooting Table}{p{0.3\textwidth} p{0.6\textwidth}}
|
|
\textbf{Symptom} & \textbf{Corrective Action} \\
|
|
\hline
|
|
|
|
No LED but good video display. &
|
|
Remove the LED bezel assembly and check for a good connection.
|
|
|
|
\vspace*{0.8em}
|
|
Replace the LED.
|
|
|
|
\vspace*{0.8em}
|
|
Ensure proper cable connections fr.om.the deflection board
|
|
to the LED bezel assembly.
|
|
\\
|
|
Video display but not to specifications. &
|
|
Bring up the appropriate monochrome display alignment
|
|
pattern (TESTS 60, 61, or 62) and perform the adjustment
|
|
according to \hyperlink{chapter.4}{Chapter 4}.
|
|
\\
|
|
\end{tblcont}
|